Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - DBL POLE
Sort By:
Page of 2
BREAKER DUPLEX PLUGIN 2-1P 15A Homeline Square D CHOM Standard Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker
Eaton Circuit Breaker, Duplex, Type DNPL, 120 VAC, 15 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Independent, Wire Size: 14 to 4 AWG, Terminal Type: Plug-In, Dimensions: 3 in L x 1 in W x 3 in H, Suitable for: CPM, CPL, CBRPM, CBRPL Load Center Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 15 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Trip Sensitivity: 6 mA, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3 in H, 104 deg F Operating Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 20 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Trip Sensitivity: 6 mA, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3 in H, 104 deg F Operating, Suitable for: Air Conditioning, Heating and Refrigeration
BREAKER DUPLEX PLUGIN 1-1P 20A BR215 15A 2POLE CIRCUIT BREAKE BREAKER DUPLEX PLUGIN 2-1P 20A
Eaton Circuit Breaker, Duplex, Type DNPL, 120 VAC, 15 to 20 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Independent, Wire Size: 14 to 4 AWG, Terminal Type: Plug-In, Dimensions: 3 in L x 1 in W x 3 in H, Suitable for: CPM, CPL, CBRPM, CBRPL Load Center Eaton type BR plug-in breakers in the standard 1 in per pole molded case and can be used as main and/or branch disconnect devices, all are CSA and UL listed, typical ampacity range for BR breakers is 15 through 125 A. Eaton Circuit Breaker, Duplex, Type DNPL, 120 VAC, 20 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Independent, Wire Size: 14 to 4 AWG, Terminal Type: Plug-In, Dimensions: 3 in L x 1 in W x 1 in H, Suitable for: CPM, CPL, CBRPM, CBRPL Load Center
Homeline Square D CHOM Standard Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker CIRCUIT BRKR TBA 2P2SPC 20/20A
Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 40 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Trip Sensitivity: 6 mA, 8 to 2, 8 to 2 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3 in H, 104 deg F Operating Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 30 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Trip Sensitivity: 6 mA, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3 in H, 104 deg F Operating, Suitable for: Air Conditioning, Heating and Refrigeration Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker.
BRKR CIRC 2 POLE 15A 240V     Qwik Open Square D QO Standard Circuit Breaker BR230 30A 2POLE CIRCUIT BREAKE
Siemens Circuit Breaker, 120/240 V, 15 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Frame Type: QP, Frame Size: 2 in, Trip Type: Thermal Magnetic, Wire Size: 14 to 6 AWG, Terminal Type: Lug, Plug-In Mounting, Dimensions: 3 in L x 3 in W x 2 in H, Operating Temperature: 40 deg C The industry leader in circuit protection is easily recognized by the industry's only trip indicator. The red Visi-Trip? Indicator makes it easy to spot a tripped circuit breaker. Compact 3/4 in wide format for one-pole circuit breakers helps minimize panel space and footprint. The Square D? exclusive Qwik-Open? protection is standard on all 15 A and 20 A circuit breakers trip reaction within 1/60th of a second. No other circuit breaker trips faster. Eaton's residential BR circuit breakers are used in load centers, panelboards or similar devices. They are made for a wide range of applications and include BR 1 in circuit breakers and accessories for BR-style load centers, arc fault circuit interrupters (AFCI) and ground fault circuit interrupters (GFCI).
CIRCUIT BRKR TBA 2P2SPC 40/40A Qwik Open Square D QO Standard Circuit Breaker BRKR CIRC 2 POLE 20A 240V
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. The industry leader in circuit protection is easily recognized by the industry's only trip indicator. The red Visi-Trip? Indicator makes it easy to spot a tripped circuit breaker. Compact 3/4 in wide format for one-pole circuit breakers helps minimize panel space and footprint. The Square D? exclusive Qwik-Open? protection is standard on all 15 A and 20 A circuit breakers trip reaction within 1/60th of a second. No other circuit breaker trips faster. Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total).
Qwik Open Square D QO Standard Circuit Breaker Qwik Open Square D QO Standard Circuit Breaker BREAKER DUPLX BOLT-ON 2-1P 20A
The industry leader in circuit protection is easily recognized by the industry's only trip indicator. The red Visi-Trip? Indicator makes it easy to spot a tripped circuit breaker. Compact 3/4 in wide format for one-pole circuit breakers helps minimize panel space and footprint. The Square D? exclusive Qwik-Open? protection is standard on all 15 A and 20 A circuit breakers trip reaction within 1/60th of a second. No other circuit breaker trips faster. The industry leader in circuit protection is easily recognized by the industry's only trip indicator. The red Visi-Trip? Indicator makes it easy to spot a tripped circuit breaker. Compact 3/4 in wide format for one-pole circuit breakers helps minimize panel space and footprint. The Square D? exclusive Qwik-Open? protection is standard on all 15 A and 20 A circuit breakers trip reaction within 1/60th of a second. No other circuit breaker trips faster. Eaton Replacement Classic Circuit Breaker, Duplex, Type BQL, 120 VAC, 20 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Non-Interchangeable, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 3-1/2 in L x 1 in W x 3-1/2 in H, Includes: Captive Line Screw
BREAKER BR 2P 50 AMP 10KA     BREAKER BR 2P 60 AMP 10KA     BRKR CIRC 2 POLE 30A 240V
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 V. 10 kAIC, 10,000 AIR. 2 spaces, 2 in per breaker. Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total).
BRKR CIRC 15A 240V BLK        BREAKER CIRCUIT 2POLE 1IN 30A BREAKER CIRCUIT 2POLE 1IN 40A
THQP breakers are a smaller, smarter solution for today's cost and quality-conscious contractors and homeowners. Half the width of standard breakers, they allow use of smaller load centers and for maximum savings of space and money. GE is the only manufacturer that gives you this cost advantage without sacrificing flexibility. THQP breakers are one-half the width of standard GE breakers but identical in design. Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 Cu or 12 to 8 Al AWG wire, 30 to 50 A 8 to 4 Cu or 8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 Cu or 12 to 8 Al AWG wire, 30 to 50 A 8 to 4 Cu or 8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
BREAKER CIRCUIT 2POLE 1IN 20A BRKR CIRC 50A 120/240V 2 POLE BRKR CIRC 2 POLE 40A 240V
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 Cu or 12 to 8 Al AWG wire, 30 to 50 A 8 to 4 Cu or 8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR. Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total). Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total).
BREAKER BOLT-ON 2P 60 AMP     BREAKER CIRC BOLT ON 15A 2POLE BREAKER CIRC BOLT ON 20A 2POLE
Eaton Replacement Classic Circuit Breaker, Type BQL, 120/240 VAC, 60 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Standard, Wire Size: 8 to 2/0 AWG, Terminal Type: Bolt-On, Dimensions: 5 in L x 3 in W x 2 in H, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw Cutler-Hammer Circuit Breaker, 120/240 VAC, 15 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 2 in H, Includes: Captive Line Screw Cutler-Hammer Circuit Breaker, 120/240 VAC, 20 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 2 in H, Includes: Captive Line Screw